PQUAN Technology PQ580-SF series of high-protection inverters represents a cutting-edge solution for demanding applications in harsh environments (such as those with high levels of dust, heavy metals in coal mines, smelting operations, humid conditions, chemical plants, etc.). Boasting an IP65 protection rating (waterproof, moisture-proof, dustproof, and corrosion-resistant), advanced vector control, and excellent communication bus support with RS-485 (MODBUS) functionality, this inverter offers unparalleled reliability and efficiency for three-phase permanent magnet synchronous and three-phase asynchronous motor drives. Its user-friendly interface and comprehensive protection features make it a preferred choice for various industries, including fans, pumps, and industrial automation.
+ Vector speed control (IMSVC) of asynchronous motor
+ Vector speed control (FMSVC) of synchronous motor
+ Waterproof PG heads as wire holes,designed for harsh environments
+ Support V/F control or SVC open circuit vector control mode
+ Employs the latest generation IGBT power modules for quiet operation.
+ Output frequency Max 3000Hz.
+ Operates with a carrier frequency of 0.5 to 15KHz
+ Torque boost function of the electric motor by up to 30%
+ Standard built-in brake unit for 0.4KW- 30KW
+ Built-in PID, PLC, AVR, JOG, Timers, protections, EMC filter
+ Safety function EMS emergency machine stop
+ MODBUS support standard RS-485 physical communication interface
+ 6 digital inputs, including 1 high-speed 20KHz pulse;
+ 2 analog inputs are integrated input 0-10V and 4-20 mA input terminal
+ 1 digital , 2 analog output support 0~20mA or 0~10V
+ 2 relay output terminal
▌PQ580SF VFD Characteristics:
▌Application:
Outdoor: Good dust and splash protection for applications like agricultural irrigation, fountains, and outdoor lighting.
Industrial: Reliable in dusty, non-high-pressure washdown industrial settings like light production and material handling.
Humid: Suitable for damp, splash-prone environments such as aquaculture and non-direct washdown areas in food processing.
Item | Specifications | |
Input Output | Voltage Range | Input: 1 Phase 220V±15%, Output: 3 Phase 200~240V, |
Input: 1 Phase 220V±15%, Output: 3 Phase 380~440V, | ||
Input: 3 Phase 220V±15%, Output: 3Phase 200~240V, | ||
Input: 3 Phase 380V±15%, Output: 3Phase 380~440V, | ||
Basic Function | Motor Type | asynchronous motor |
Permanent magnet synchronous motor | ||
Maximum Frequency | Vector Control:0~300Hz V/F Control:0~3000Hz | |
Carrier Frequency | 0.5kHz~15kHz; the carrier frequency will be automatically adjusted according to the load characteristics. | |
Input Frequency Resolution | Digital Setting: 0.1Hz | |
Analog Setting: 0.01V corresponding maximum frequency ×0.025% | ||
Control Mode | Open loop vector control,V/F control, torque control, PID | |
Startup Torque | Open loop vector control:0.5Hz 180%, V/F control:0.5Hz 150% | |
Speed adjustableRange | Open loop vector control 1:200, V/F control: 1:100 | |
Steady-state Speed Accuracy | Open loop vector control ±0.2%, V/F control ±0.5% | |
Torque Control Accuracy | ±5%(SVC) | |
Overload Capability | G type: 150% rated current 60s,180% rated current 3s | |
P type: 120% rated current 60s,150% rated current 3s | ||
Torque Boost | Automatic Torque Boost, Manual Torque Boost 0.1%~30.0% | |
V/F Curve | Line Type、Multi-point Type, N-power V/F curve | |
Ramp mode | Straight-line ramp; S-curve ramp; | |
Four groups of acceleration/deceleration time with the range of 0.0 to 3200.0s. | ||
DC Brake | DC Brake Frequency:0.00Hz to maximum frequency. | |
Brake time: 0.0s to 36.0s | ||
Braking operation current value: 0.0%~100.0% | ||
Simple PLC multi-speed operation | Realize up to 16-speed operation through built-in PLC or control terminal. | |
Onboard PID | It realizes process-controlled closed loop control system easily. | |
Automatic Voltage Regulator (AVR) | Automatically regulates the output voltage to maintain a constant level regardless of grid voltage fluctuations. | |
Over-voltage/current Stall Control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current. | |
Fault current limiter | Protect the inverter by minimizing overcurrent conditions. | |
Torque limiting and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. | |
Tailored options | Excellent performance | Implement motor control using advanced current vector control. |
Fault-tolerant: | Regenerative braking during a power sag enables the inverter to sustain operation. | |
Timing Control | Timing control function:set time range 0.0~3200.0Min | |
Bus Support | RS-485:Modbus | |
Running | Running Command Source | Operation panel/Control terminals/Serial communication port. You can perform switchover between these sources in various ways. |
Frequency Source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Auxiliary frequency source | 10 kinds of auxiliary frequency sources. Flexible realization of auxiliary frequency fine-tuning and frequency synthesis. | |
Control Signal Input Terminal | 6 digital input terminals, one of which supports up to 20 kHz high-speed pulse input. | |
2 analog input terminals, one of which only supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. | ||
Control Signal Output Terminal | 1 digital output terminal; | |
2 relay output terminal; | ||
2 analog output terminal that supports 0-20 mA current output or 0-10 V voltage output; | ||
Control panel | LED DISPLAY | Five-digit numerical readout |
Key locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. | |
25 Protection Function | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection. | |
Environment | Installation environment | Inside, avoid direct sunlight, salt, dust, corrosive or flammable gas, smoke, steam. |
Altitude | Below 1000 meters above sea level. (reduce the load level when used above 1000 meters above sea level) | |
Ambient Temperature | -10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9m/s (0.6g) | |
Structure | Protection level | IP20 |
Cooling method | Forced air cooling | |
Installation method | Wall-mounted, floor-standing electric control cabinet. |